Joined ’Japan Microscope Manufacturers’ Association’
Luceo has joined ’Japan Microscope Manufacturers’ Association’ as a supporting member.
In 1966, when liquid crystals did not exist, we took notice of polarizing plates, an optical element, and began our in-house R&D, production and sales. As time passed, we began doing the same for wave plates, which is now adopted by major microscope manufacturers, becoming a confident product of our company. In 1996, we developed, manufactured and sold original strain tester using our own polarizing plates and wave plates. Luceo has always made progress and evolved by having flexibility to the change of times. We aspire to become a niche-top company in these fields by continuing to develop products in our brand.
・The single wave plate is capable of achieving constant phase difference with high precision in the range of 450nm to 1,100nm with its super broadband range.
・Retardance Tolerance:±λ1/50(450nm≦λ1<550nm)、±λ2/80(550nm≦λ2≦1,100nm)
・Sizes larger than crystals can be manufactured. It also supports various sizes and shapes (square, etc.) (~φ100mm、~□100mm).
・For applications requiring multiple wave plates, SB-RETAX will provide the solution with just one plate.
・Enables faster data synthesis and miniaturize device development.
For example, solar observation requires multiple wavelengths simultaneously and each wave length data is compared and synthesized for analysis. Conventional wave plates that support single wavelengths cannot perform simultaneous observations, so time lags occurred when comparing data and extended time is required for synthesis. By having a single wave plate perform multiple observations simultaneously, it provides accuracy and shortened work time.
In addition, when switching wave plates, space within the device itself or the structural space would be required, but with SB-RETAX, these spaces become unnecessary, which could lead to miniaturization of devices.
・Contributes to the development of truly innovative ideas.
・Simulations allow adjustments to any wavelength range and retardation (maximum wavelength range of 450 to 1,100nm).
・For example, we offer standard products supporting wavelength range of 450~700nm、500~800nm、600~900nm and 800~1,100nm (Retardance Tolerance: ±λ/80,Parallelism and Surface Quality: For φ30 (Parallelism 4 arc min, 4 fringes), parallelism of 1 arc min can be provided upon customized order.)
・Customized orders available from just 1 pc.
・Polarizing plate made by our original brand
・Because we perform the R&D and manufacturing, customers may select from a variety of standard products. The supported wavelength range for visible light is 400~680nm and near infrared is 780~1,600nm.
・In addition to standard products, we offer customization from just 1 plate.
(POLAX is an original brand by LUCEO)
・Various sizes available (Diameter, thickness) (~φ100mm×4t ~□100mm×4t (Axis parallel to edge), thickness: 1t~)
Improved in-plane color regularity: ~ φ50mm、~□50mm×2t (Axis parallel to edge). Our company was the first to develop polarized plates that cuts-off short wavelengths (prevention of blue-leak phenomenon). Even today, we are improving our technology. LUCEO quality is recognized worldwide as our products are integrated into products of globally famous major microscope manufactures and national astronomical observatories.
・This polarizer has a film laminated in between the glass substrates. It is a known fact that, generally, it is difficult to attain parallelism and surface quality with laminated products, but our polarizing plates possess high quality parallelism and surface quality, as well as transmitted wavefront quality.
For example, φ30×2t:Parallelism 3 arc min (Customized: ~ 30 arc sec) 3 fringes
・High level of axis accuracy (~±1 deg.)
・Measurement data may be attached
・Wave plate made by original brand
・Because we manufacture the wave plates in-house, we are able to offer wave plates made to your preferred wavelength (retardation or phase difference) from just 1 plate (Maximum phase difference available: 560nm per 1 film. By layering multiple wave films, we offer phase difference over 1,000nm as well)
・You may select from the 2 types of wave films we offer for your needs.
Original Brand Name | RETAX | HI-RETAX |
Maximum Size (Seamless size) |
Phase difference: appx.140nm φ140mm □140mm (Axis parallel to edge) Phase difference: appx. 530nm φ30mm □30mm (Axis parallel to edge) |
Phase difference: appx. 140nm φ100mm □100mm (Axis parallel to edge) Phase difference: appx. 530nm φ60mm □60mm (Axis parallel to edge) |
Thickness | Size:~φ60 Thickness:appx. 1mm or more Size:φ60~φ140 Thickness:appx. 2mm or more |
Size:~φ100 Thickness:appx. over 2mm |
Price | Custom orders are lower priced than HI-RETAX (Recommended) |
Standard products are same price as RETAX |
Heat resistance temperature | Approximately 40℃ | Appx. 70℃ (Recommended) |
Retardance Tolerance | Within 1nm(φ30mm, appx. 140nm phase difference) Within 4nm(φ30mm, appx. 530nm phase difference) |
Within 1nm(φ30mm, appx. 140nm phase difference) Within 4nm(φ30mm, appx. 530nm phase difference) |
Parallelism & Surface quality | φ30×2t:Parallelism 3 arc min (Customized: ~ 30 arc sec) 3 fringes |
φ30×2t:Parallelism 3 arc min (Customized: ~ 30 arc sec) 3 fringes |
Polarized observation of color by sensitive tint plate (red tint) | Differs from crystal wave and mica wave plates | Same as crystal wave and mica wave plates (Recommended) |
※The available size and thickness will vary depending on phase difference and optical axial direction.
※In addition to standard products, we make custom orders from just 1 plate
※Custom made orders are available for coating types, sizes and shapes.
・Circularly polarizing plate is made by laminating polarizing and wave plates (1 / 4λ phase difference).
・Polarizing plate (POLAX) and Wave plate (RETAX、HI-RETAX) from our original brands are used so we are able to offer a variety of circularly polarizing plates. (Available wavelength range: visible light (400~680nm) and near infrared (780~1,600nm))
・In addition to standard products, we make custom orders from just 1 plate
・Various sizes available (Diameter, thickness). (RETAX:~φ50mm X 2t, ~□50mm X 2t)
・High level of axis accuracy (~±2 deg.)
※As phase difference becomes larger, than the available size becomes smaller.
Luceo has an ISO 9001:2015 certified Quality Management System.
Optical filters are tested and evaluated throughout the manufacturing process. Spectrophotometers and optical measuring instruments are calibrated and maintained to meet the requirements of our Quality System.
Optical filters are 100% inspected before shipping.
NEW PRODUCTS
・The physical unit of a strain, the retardation (phase difference), is measured quantitatively (in nanometer units). Furthermore, retardation can be converted into stress (MPa or kg/cm2) by entering the sample’s photoelastic constant and thickness.
・By feeding back the measurement into development, it can contribute to reducing defective parts. It is also effective in setting mold conditions as wells as process management of resin molded parts.
・Due to its wide measurement area of φ150 mm, it is best suited for measuring large samples.
・It is capable of measuring large strain of glass or plastic depending on the generated amount of the strain.
・YES, it’s Made in Japan
Contact us to see how Luceo works with our customers to solve complex metrology problems.
Measure:
Glass, Stress Birefringence, Display Components, Injection Molded Plastics, Fiber Optics, Lens Blanks, Lenses, Birefringent Crystals and others.
Simply set the measurement target and press the measurement start button.
The retardation measurement result is displayed.
The obtained 2D data can be graphed and compared with the analysis function.
principle of stress measurement
Please note!
The similar products of our LSM series are out on market in China.
If you have any concerns, please feel free to contact us.
Luceo has joined ’Japan Microscope Manufacturers’ Association’ as a supporting member.
Presentation of Professor emeritus Kiyoshi Ichimoto, Kyoto University will be held at ’SPIE Astronomical Telescopes + Instrumentation’ as follows. Super Broadband Waveplate(SB-RETAX) is one of Luceo product, it’s utilized in …
’SPIE Astronomical Telescopes + Instrumentation’ will be held at Pacifico Yokohama from June 18th (Tuesday) to 20th (Thursday), 2024. We look forward to your visit. And also looking for distributors …
■About the use of polarized light by mantis shrimp Have you heard of mantis shrimp? Mantis shrimp are interesting creatures that live in the sea, and their eyes are very unique. They use a property……
Photonics West is the largest event in North America on optical technology, held annually from late January to early February in San Francisco. As a newcomer who joined Luceo in 2022, I would like to ……
■The 3rd Future Great Inventor Contest in Itabashi In Itabashi City, it is held every year to improve children’s imagination and explanation skills and increase their interest in manufacturing. Winne……
■Google Bard What is Google Bard? It is a generative AI developed by Google. Google Bard is a generative AI developed by Google and said to be a partner that can help us in our lives by improving cr……
■ Definition of Strain This page is about the definition of strain in Luceo. ■ Stress, Strain In Luceo, we use the word "strain" as following meaning. We say "There is strain" or "Strain remains……